Original Image: Alpha Technologies – FlexNet MPS 48-7

Alpha Technologies – FlexNet MPS 48-7

MPS48-7

Wireless Infrastructure | Power Systems | UPS

  • In situations of extended power outages, Alpha offers its FlexNet MPS48-7, a power supply platform providing primary and standby power for outdoor mesh network access point.

    • Up to 18 hours backup power during utility outagesAlpha Technologies UPS Protection for Extended Power Interruptions
    • Configurable input voltages for worldwide applications
    • Status monitoring interface with network
    • Preconnectorized cables for safe and simple installation

    {tab=Battery Specifications}

    Type: Four Valve Regulated Lead Acid (VRLA) (Batteries sold separately)
    Capacity: 7.7Ah float service
    Runtime @ 25C / 77F: 18hrs 20W load, 8hrs 40W load
    Alarms:

    Data communication with Aironet AP includes:

    Input Voltage Output Power Battery Temperature Output Voltage Battery Voltage Battery Current

    {tab=Input Specifications}

    Voltage Range: 90 to 132, or 180 to 264Vac (switch selectable) or 250 to 305Vac with optional step-down transformer
    PV Array Capacity: 50 to 60Hz
    Surge Protection: ANSI/IEEE Std. C62.41 to Category A, B, or C requirements, using a “Ring Wave” or “Combination” waveform, at a level of 6kV
    Voltage: 42 to 56Vdc
    Power: 50W continuous max. (Including auxiliary output)
    Transfer Characteristics Uninterrupted upon loss of AC service

    {tab=Mechanical Specifications}

    Dimensions (in/mm): 17.5H x 12.75W x 5.25D / 445H x 324W x 133D
    Weight (lb/kg): 11 / 4.9 (not including battery)
    Operating Temperature With Heater Option (without heater option): -40 to 55C (-20 to 55C) / -40 to 131F (-4 to 131F)
  • Documents